Total
Body Irradiation
TBI Stand
"Total
Body Photon or Electron Beam Irradiation"
Catalog
# 9205 |
|
The
TBI Stand greatly facilitates treatments of patients in a
standing but supported position while offering the
highest degree of patient comfort, patient safety and accurate
treatment reproducibility. |
|
|
TBI
Stand now available with Scatter Screen, Hanging Lung
Block Jackets, Head Holder and Dose Verification Provision!
|
|
| Features:
- Improved
Patient Comfort
- Patient Safety
- Accurate Shielding Block
Positioning
- Safe Mounting of Shielding
Blocks
- Consistent Film Verification
- Ease of Set-Up
- Stable and Rigid Construction
- Reproducible Settings
|
| |
| |
TBI
Stand Technical Specifications:
TBI Stand - Catalog #
9205
Tallest Person:
78 inch (198cm)
Shortest person: 42 inch (I 07cm)
Overall Height: 78 inch (I 98cm)
Overall Width: 36 inch (91.5cm)
Overall Depth: 26 inch (66cm)
Overall Weight: 196 lbs (89.09kg)
Max. Caster Weight Load: 600 lbs (272.7kg)
Max. Seat Weight Load: 250 lbs (I 13kg)
Electrical Requirements: None
Installation Requirements: None |
 |
Scatter
Screen Technical Specifications:
Scatter
Screen--Catalog # 9205-SS
Overall Height:
83 inch (210.8cm)
Overall Width: 48
inch (121.9cm)
Overall Depth: 36
inch (91.4cm)
Overall Weight 1/2"
Screen: 195 lbs (88.63kg)
Overall Weight 3/4"
Screen: 230 lbs (I04.5kg)
Max. Caster Weight Load:
600 lbs (272.7kg)
Materials: Welded Steel Tubing
and Acrylic
Installation Requirements:
Minimal (Instructions Included)
|
References:
Peters, W P , Bone Marrow
Transplantation In Weiss, G R , editor Clinical Ocology Norwalk,
CT Appleton and Lange. 1993 91-96
Curran, W J , Galvin, J M.,
D'Angio, G I A Simple Dose Calculation Method for Total
Body Photon Irradiation Int I Radial Oncol Biol Phys 17:219-224,
1989
El-Khatib, E E , Valcourt,
S Calculation of Lung Shielding for Total Body irradiation Int
J. Radiat.1, Oncol. Biol. Phys. 17:1099-1102, 1989
Travis, E L, . Lung morbidity
of radiotherapy, In Plowman, P N McElwain, T J Meadows, A T
, eds Complications of cancer management Oxford Butterworth-Heineman,
Ltd . 1991 232249
Med Phys Sept-Oct 1985, 120)
639-645 Podgorsak EB Pla C Evans MDC Pla M The influence of
phantom size on output, peak scatter factor, and percentage
depth dose in large-field photon irradiation
Med Phys May-Jun 1988, 15(3)
364-369 Kirby TH Hanson WIF Cates DA verification of total body
photon irradiation dosimetry
Techniques.
The Physical Aspects of Total
and Half Body Photon Irradiation.
AAPM Report Series Booklet
17 (1986)
Med Phys Mar 1996, 23 Hussein
S Kennelly GM Lung compensation in total body irradiation. |
| |
|
|