Mick Radio-Nuclear Instruments
brachytherapy
 Print Page
The Mick® Interstitial HDR Implant System
The Mick Interstitial HDR Implant System
This methodology is suitable for Brachytherapy involving Oral Cavity Tumors, Oropharygeal Tumors, Neck Tumors and Soft Tissue Sarcomas.
 
System Highlights
CT Compatible for image-based treatment planning.
Standard length source-guides for improved QA of treatment geometry.
Variable length catheters for patient comfort.
Collet fixation ensures integrity of catheters and source-guides.
HIGH-DOSE-RATE BRACHYTHERAPY
TREATMENT DELIVERY
CT BASED HIGH-DOSE-RATE TREATMENT PLANNING
HDR Remote Afterloading System Connected to Embedded & Sutured Catheters
CT Based Compatible Components Enable Visualization of Implant Geometry
Implant Procedure and High-Dose-Rate Tretament
This System is currently compatible with Varian® Afterloading Systems
HDR Interstitial Implant Set:

The design of this implant set was motivated by the need of a system that - in addition to standard features (can be implemented in various anatomical sites, may be used for out-patient treatment) - makes use of fixed (after-loader specific) channel length, and is compatible with any standard imaging modality (X-ray, CT, and MRI).

The system consists of trocars (needles), catheter-sleeves that are inserted into the treatment site surgically, and trimmed to conform to the size of the treated area. Collet type semi-spherical buttons fix the catheters to the patient and filaments are used to keep the catheters from collapsing or kinking, while at the same time providing enhanced visu- alization of the catheters in CT images. Standard length source guides (130 cm) are used to transport the source through the sleeves. Double collet buttons fix the source guides to the sleeves, while maintaining channel integrity for safe treatment delivery.
The Mick Interstitial HDR Implant System as of 07/12/06
 
Description
Cat. No
Material
Sterilization
Patient Contact
1.
HDR Interstitial Needle - Straight - 11GA x 20CM
2001-20S
Stainless Steel
Steam Autoclave
Yes
2. HDR Interstitial Needle - Medium Curve - 11GA x 20CM
2001-20MDC
Stainless Steel Steam Autoclave Yes
3. HDR Interstitial Needle - Maximum Curve - 11GA x 20CM 2001-20MXC Stainless Steel Steam Autoclave Yes
4.
HDR Interstitial Needle - Straight - 11GA x 30CM
2001-30S Stainless Steel Steam Autoclave Yes
5. HDR Interstitial Needle - Medium Curve - 11GA x 30CM 2001-30MDC Stainless Steel Steam Autoclave Yes
6. HDR Interstitial Needle - Maximum Curve - 11GA x 30CM 2001-30MXC Stainless Steel Steam Autoclave Yes
7. 13GA Catheter x 45CM 2001-11 Celcon ETO Yes
8. 13GA Catheter x 65CM 2001-12 Celcon ETO Yes
9. 13GA Catheter x 45CM With 45CM Leader 2001-10 Celcon ETO Yes
10. 1.9MM Catheter x 1300MM Long 2001-13 Celcon ETO No
11. 13GA Suture Button 2001-SB Delrin - USP Class IV ETO & Steam Autoclave Yes
12. 13GA / 1.9MM Combo Collet 2001-CC Delrin - USP Class IV ETO & Steam Autoclave Yes
13. 13GA HDR Catheter x 45CM With Button 0320-02 Celecon & Delrin USP Class IV Titanium Screw ETO Yes
14. 13GA HDR Catheter x 45CM With 45CM Leader and Button (0.070 DIA PTFE Beading) 0321-01 Celecon & Delrin USP Class IV Titanium Screw ETO Yes
15. 0.070 DIA PTFE Beading (Specify Length) 0321-02 Teflon ETO Yes
16. 13GA HDR Catheter x 45CM With 45CM Leader and Button (0.070 DIA PTFE Beading) 0321-03 Nylon Titanium Screw   No
 
All items can be purchased seperately. Items are shipped Non-Sterile.
Note: Clamping adaptors required for the connection of catheters to the afterloader can be purchased from the manufacturer directly.
 
 
 
Mick Radio-Nuclear Instruments, Inc.
Shipping and Receiving:
Peter A. Reed, Sales Representative
521 Homestead Ave.
Mount Vernon, NY 10550
Toll Free #: (877) 597-MRNI
Phone: (914) 667-3999
Fax: (914) 665-8834
Email:
518 S. Columbus Ave.
Mount Vernon, NY 10550
256 Randall Avenue
Freeport, New York 11520
Cell: (516) 972-2752
Fax: (516) 546-4753